Purpose: The purpose of this study was to evaluate whether the eye tracking system (ETS) improved the reproducibility of a single circle peripapillary retinal nerve fiber layer (RNFL) measurement acquired with spectral-domain optical coherence tomography (OCT). Materials and Methods: The sample comprised 205 individuals divided into 2 groups according to intraocular pressure and visual field outcomes. A total of 100 healthy individuals and 105 patients with open-angle glaucoma underwent imaging of the optic nerve head with OCT 3 times during the same session and 2 additional times in subsequent sessions (30 days apart). Intraclass correlation coefficient (ICC), coefficient of variation, and test-retest variability were calculated for the RNFL thickness acquired with and without the ETS enabled, and compared. Results: The glaucoma group mainly comprised patients with moderate glaucoma (mean deviation of standard automated perimetry,-6.73±6.2 dB). The RNFL thicknesses did not differ between acquisitions with or without the ETS activated and disabled. All ICCs were >0.9 in the control and glaucoma groups with or without the ETS activated. The best parameter in the intersession analysis (with ETS activated) was global RNFL thickness (ICC, 0.95; coefficient of variation, 2.7%; and test-retest variability, 2.87 μm). The reproducibility and repeatability of RNFL measurements did not differ significantly between acquisitions with or without the ETS in either group. Conclusions: The reproducibility of peripapillary RNFL thicknesses acquired with OCT was excellent. The variability between OCT measurements did not decrease with the ETS activated.

Effect of the Eye Tracking System on the Reproducibility of Measurements Obtained with Spectral-domain Optical Coherence Tomography in Glaucoma / B. Abadia, A. Ferreras, P. Calvo, P. Fogagnolo, M. Figus, A.B. Pajarin. - In: JOURNAL OF GLAUCOMA. - ISSN 1057-0829. - 26:7(2017 Jul), pp. 638-645. [10.1097/IJG.0000000000000690]

Effect of the Eye Tracking System on the Reproducibility of Measurements Obtained with Spectral-domain Optical Coherence Tomography in Glaucoma

P. Fogagnolo;
2017

Abstract

Purpose: The purpose of this study was to evaluate whether the eye tracking system (ETS) improved the reproducibility of a single circle peripapillary retinal nerve fiber layer (RNFL) measurement acquired with spectral-domain optical coherence tomography (OCT). Materials and Methods: The sample comprised 205 individuals divided into 2 groups according to intraocular pressure and visual field outcomes. A total of 100 healthy individuals and 105 patients with open-angle glaucoma underwent imaging of the optic nerve head with OCT 3 times during the same session and 2 additional times in subsequent sessions (30 days apart). Intraclass correlation coefficient (ICC), coefficient of variation, and test-retest variability were calculated for the RNFL thickness acquired with and without the ETS enabled, and compared. Results: The glaucoma group mainly comprised patients with moderate glaucoma (mean deviation of standard automated perimetry,-6.73±6.2 dB). The RNFL thicknesses did not differ between acquisitions with or without the ETS activated and disabled. All ICCs were >0.9 in the control and glaucoma groups with or without the ETS activated. The best parameter in the intersession analysis (with ETS activated) was global RNFL thickness (ICC, 0.95; coefficient of variation, 2.7%; and test-retest variability, 2.87 μm). The reproducibility and repeatability of RNFL measurements did not differ significantly between acquisitions with or without the ETS in either group. Conclusions: The reproducibility of peripapillary RNFL thicknesses acquired with OCT was excellent. The variability between OCT measurements did not decrease with the ETS activated.
glaucoma; OCT; optic nerve head; optical coherence tomography; retinal nerve fiber layer; Adult; Aged; Female; Glaucoma, Open-Angle; Humans; Intraocular Pressure; Male; Middle Aged; Nerve Fibers; Optic Disk; Prospective Studies; Reproducibility of Results; Retinal Ganglion Cells; Tomography, Optical Coherence; Tonometry, Ocular; Visual Acuity; Visual Fields; Eye Movements; Ophthalmology
Settore MED/30 - Malattie Apparato Visivo
lug-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
00061198-201707000-00007.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 136.25 kB
Formato Adobe PDF
136.25 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/528082
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact