PURPOSE: While extensive references are present in the literature dealing with the correlation between subjective and objective evaluation of tooth shade, there is a lack of information on this correlation regarding the soft tissue color. The purpose of this experimental study was to verify whether a correlation between the objective and subjective evaluation exists in analyzing soft tissue color. MATERIAL AND METHODS: A total of 39 patients with at least one implant-supported restoration in the anterior maxilla were included in the study. The shade of the peri-implant mucosa was compared with the shade of the gingiva at the adjacent tooth in a subjective and in an objective manner. The subjective evaluation was performed by five dental professionals (prosthodontist, periodontist, general dentist, dental hygienist, and dental assistant) in a subjective scale (ranging from 1 to 4). The objective evaluation was obtained by means of a spectrophotometer in a CIELAB* Color Scale, and the differences were evaluated through formula ΔE=[(ΔL)2+(Δa)2+(Δb)2]1/2. To correlate the subjective and the objective evaluation, for each arithmetical median value of the subjective evaluation, a mean value of objective evaluation has been calculated, and the Spearman's rank correlation coefficient has been used. The differences have been also analyzed for thin and thick tissue biotypes. RESULTS: The mean ∆E value for the subjective evaluation between peri-implant soft tissue and adjacent tooth gingival tissue was ∆E = 9.74. Also, mean ∆E values of 10.35 and 7.54 have been reported for thin and thick biotypes, respectively. Mean values of ∆E = 6.63, 8.54, and 15.54 were presented by median values of 1 (perfect matching), 2 (good matching), and 3 (clinically distinguishable), respectively. The threshold for the distinction of differences of mucosal color by the human eyes between perfect or good matching and distinguishable values has been calculated in ∆E = 8.74. CONCLUSIONS: Within the limitation of this study, a correlation between the subjective and the objective evaluation of the peri-implant soft tissue exists and the threshold for the distinction of mucosal color differences between perfect or good matching and distinguishable subjective values has been calculated in ∆E = 8.74 in the objective evaluation.

Correlation between subjective and objective evaluation of peri-implant soft tissue color / G. Paniz, E. Bressan, E. Stellini, E. Romeo, D. Lops. - In: CLINICAL ORAL IMPLANTS RESEARCH. - ISSN 0905-7161. - 25:8(2014), pp. 992-996. [Epub ahead of print] [10.1111/clr.12201]

Correlation between subjective and objective evaluation of peri-implant soft tissue color

E. Romeo
Penultimo
;
D. Lops
Ultimo
2014

Abstract

PURPOSE: While extensive references are present in the literature dealing with the correlation between subjective and objective evaluation of tooth shade, there is a lack of information on this correlation regarding the soft tissue color. The purpose of this experimental study was to verify whether a correlation between the objective and subjective evaluation exists in analyzing soft tissue color. MATERIAL AND METHODS: A total of 39 patients with at least one implant-supported restoration in the anterior maxilla were included in the study. The shade of the peri-implant mucosa was compared with the shade of the gingiva at the adjacent tooth in a subjective and in an objective manner. The subjective evaluation was performed by five dental professionals (prosthodontist, periodontist, general dentist, dental hygienist, and dental assistant) in a subjective scale (ranging from 1 to 4). The objective evaluation was obtained by means of a spectrophotometer in a CIELAB* Color Scale, and the differences were evaluated through formula ΔE=[(ΔL)2+(Δa)2+(Δb)2]1/2. To correlate the subjective and the objective evaluation, for each arithmetical median value of the subjective evaluation, a mean value of objective evaluation has been calculated, and the Spearman's rank correlation coefficient has been used. The differences have been also analyzed for thin and thick tissue biotypes. RESULTS: The mean ∆E value for the subjective evaluation between peri-implant soft tissue and adjacent tooth gingival tissue was ∆E = 9.74. Also, mean ∆E values of 10.35 and 7.54 have been reported for thin and thick biotypes, respectively. Mean values of ∆E = 6.63, 8.54, and 15.54 were presented by median values of 1 (perfect matching), 2 (good matching), and 3 (clinically distinguishable), respectively. The threshold for the distinction of differences of mucosal color by the human eyes between perfect or good matching and distinguishable values has been calculated in ∆E = 8.74. CONCLUSIONS: Within the limitation of this study, a correlation between the subjective and the objective evaluation of the peri-implant soft tissue exists and the threshold for the distinction of mucosal color differences between perfect or good matching and distinguishable subjective values has been calculated in ∆E = 8.74 in the objective evaluation.
Peri-implant biotype; Peri-implant soft tissue; Spectrophotometer
Settore MED/28 - Malattie Odontostomatologiche
2014
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/223038
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 30
social impact