The results obtained from 85 antidiabetic centers enrolled in the DAI study are presented with regard to the external quality assessment scheme for glycohemoglobin. The materials have been prepared by a laboratory of the network of reference laboratories of the International Federation of Clinical Chemistry (IFCC). To each control a Diabetes Control and Complications Trial (DCCT) traceable target value was assigned. The High-Performance Liquid Chromatography (HPLC) methods for glycohemoglobin are used in 75% of the centers, the immunochemical techniques in 21% and less than 5% is using affinity chromatography based methods. The data collected from the laboratories who completed the set of measurements show that 64% of the centers are well aligned to the DCCT system. The reproducibility of the methods varied between 3.7 and 5.8% (as CV, %) and has to be improved.

Standardizzazione dell’emoglobina glicata nell’ambito dello studio DAI / A. Mosca, R. Paleari. - In: ANNALI DELL'ISTITUTO SUPERIORE DI SANITÀ. - ISSN 0021-2571. - 39:2(2003), pp. 145-151.

Standardizzazione dell’emoglobina glicata nell’ambito dello studio DAI

A. Mosca
Primo
;
R. Paleari
Ultimo
2003

Abstract

The results obtained from 85 antidiabetic centers enrolled in the DAI study are presented with regard to the external quality assessment scheme for glycohemoglobin. The materials have been prepared by a laboratory of the network of reference laboratories of the International Federation of Clinical Chemistry (IFCC). To each control a Diabetes Control and Complications Trial (DCCT) traceable target value was assigned. The High-Performance Liquid Chromatography (HPLC) methods for glycohemoglobin are used in 75% of the centers, the immunochemical techniques in 21% and less than 5% is using affinity chromatography based methods. The data collected from the laboratories who completed the set of measurements show that 64% of the centers are well aligned to the DCCT system. The reproducibility of the methods varied between 3.7 and 5.8% (as CV, %) and has to be improved.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2003
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/8424
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact