Background. Sentinel lymph node biopsy (SLNB) is an accurate alternative to complete axillary lymph node dissection (ALND) in clinically node-negative breast cancer patients. A previous breast biopsy has been considered a relative contraindication to SLNB. We examined the accuracy of SLNB by following the axillary relapses after the procedure in patients who had undergone a breast biopsy before SLNB. Patients and Methods. Up to December 2003, 4351 patients with the diagnosis of invasive breast cancer underwent SLNB at the European Institute of Oncology. Already, 543 of these patients had undergone a breast biopsy; from June 1997 to January 2004, these patients received SLNB by lymphoscintigraphy performed on the biopsy area. We followed these patients with a clinical assessment every 6 months and instrumental examinations every year, particularly focusing on the research of axillary relapse of disease. Results. In 70.4% of cases, the sentinel node was negative, and only three cases underwent further axillary dissection. The sentinel node was identified in 99% of cases and this was the only positive node in 61.5% of cases with positive axillary nodes. The median follow-up was 2 years; 4 nodal recurrences were observed: 3 axillary lymph node relapses and 1 loco-regional. Conclusions. SLNB accuracy after a previous breast biopsy is comparable with the results obtained in validation studies. SLNB after a previous breast biopsy can be considered a standard procedure. Lymphoscintigraphy identifies the sentinel node in 99% of patients.

The sentinel node biopsy after previous breast surgery : preliminary results on 543 patients treated at the European Institute of Oncology / A. Luini, V. Galimberti, G. Gatti, P. Arnone, A.R. Vento, G. Trifirò, G. Viale, N. Rotmensz, J.R. Fernandez, D. Gilardi, G. Paganelli. - In: BREAST CANCER RESEARCH AND TREATMENT. - ISSN 0167-6806. - 89:2(2005 Jan), pp. 159-163.

The sentinel node biopsy after previous breast surgery : preliminary results on 543 patients treated at the European Institute of Oncology

G. Viale;
2005

Abstract

Background. Sentinel lymph node biopsy (SLNB) is an accurate alternative to complete axillary lymph node dissection (ALND) in clinically node-negative breast cancer patients. A previous breast biopsy has been considered a relative contraindication to SLNB. We examined the accuracy of SLNB by following the axillary relapses after the procedure in patients who had undergone a breast biopsy before SLNB. Patients and Methods. Up to December 2003, 4351 patients with the diagnosis of invasive breast cancer underwent SLNB at the European Institute of Oncology. Already, 543 of these patients had undergone a breast biopsy; from June 1997 to January 2004, these patients received SLNB by lymphoscintigraphy performed on the biopsy area. We followed these patients with a clinical assessment every 6 months and instrumental examinations every year, particularly focusing on the research of axillary relapse of disease. Results. In 70.4% of cases, the sentinel node was negative, and only three cases underwent further axillary dissection. The sentinel node was identified in 99% of cases and this was the only positive node in 61.5% of cases with positive axillary nodes. The median follow-up was 2 years; 4 nodal recurrences were observed: 3 axillary lymph node relapses and 1 loco-regional. Conclusions. SLNB accuracy after a previous breast biopsy is comparable with the results obtained in validation studies. SLNB after a previous breast biopsy can be considered a standard procedure. Lymphoscintigraphy identifies the sentinel node in 99% of patients.
Settore MED/08 - Anatomia Patologica
gen-2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/47013
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 82
  • ???jsp.display-item.citation.isi??? 64
social impact