Following the IUPAC-endorsed procedure, the primary pH stds. offered by the equimolal phosphate buffer (Na2HPO4 (0.01 mol/kg-1) + KH2PO4 (0.01 mol/kg-1)) in the (N-methyl-2-pyrrolidinone + water) solvent mixt. of 50 mass percent compn. at various temps. have been detd. from p.d. measurements with the reversible Harned cell. Since the essential prerequisite of the above procedure is the knowledge of the (hitherto unknown) std. p.d. of Harned's cell, a parallel supplementary series of p.d. measurements has been carried out with the reversible cell, Pt|H2|HCl(m)|AgCl|Ag|Pt according to the classical thermodn. procedure. The problem of comparability of the pH scale in the (N-methyl-2-pyrrolidinone + water) solvent with that in the pure water solvent is duly discussed in terms of primary medium effects.

A determination of standard potentials and related primary pH standards in the 50 mass percent (N-methyl-2-pyrrolidinone + water) mixture at various temperatures / L. Falciola, P.R. Mussini, T. Mussini, M. Rossi. - In: JOURNAL OF SOLUTION CHEMISTRY. - ISSN 0095-9782. - 36:8(2007), pp. 1037-1046. [10.1007/s10953-007-9162-1]

A determination of standard potentials and related primary pH standards in the 50 mass percent (N-methyl-2-pyrrolidinone + water) mixture at various temperatures

L. Falciola
Primo
;
P.R. Mussini
Secondo
;
T. Mussini
Penultimo
;
M. Rossi
Ultimo
2007

Abstract

Following the IUPAC-endorsed procedure, the primary pH stds. offered by the equimolal phosphate buffer (Na2HPO4 (0.01 mol/kg-1) + KH2PO4 (0.01 mol/kg-1)) in the (N-methyl-2-pyrrolidinone + water) solvent mixt. of 50 mass percent compn. at various temps. have been detd. from p.d. measurements with the reversible Harned cell. Since the essential prerequisite of the above procedure is the knowledge of the (hitherto unknown) std. p.d. of Harned's cell, a parallel supplementary series of p.d. measurements has been carried out with the reversible cell, Pt|H2|HCl(m)|AgCl|Ag|Pt according to the classical thermodn. procedure. The problem of comparability of the pH scale in the (N-methyl-2-pyrrolidinone + water) solvent with that in the pure water solvent is duly discussed in terms of primary medium effects.
(N-methyl-2-pyrrolidinone + water) mixtures ; Primary pH standards ; Ag–AgCl electrode ; Electrode potentials ; HCl activity coefficients ; pH scales comparison ; Primary medium effect
Settore CHIM/02 - Chimica Fisica
Settore CHIM/01 - Chimica Analitica
2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/43675
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact