Background: Global tests of hemostasis that are used to screen patients with clinical suspicion of bleeding disorders should help the physician to identify the phase of the hemostatic system that is abnormal and guide further diagnostic workup.Patients and methods: We compared the performance of Platelet Function Analyzer-100 (PFA-100((R))) closure time (CT) with bleeding time (BT), both of which are screening tests for primary hemostasis, in the diagnostic workup of 128 consecutive patients who were screened for bleeding disorders. The sensitivities of BT and PFA-100 CT for known defects of hemostasis were evaluated; in addition, we calculated their correlation with the levels of severity of the bleeding symptoms, which were recorded using a standardized questionnaire.Results: The sensitivity of PFA-100 testing was 71% for von Willebrand disease (VWD) [with both collagen-adenosine diphosphate (C-ADP) and collagen-epinephrine (C-EPI) cartridges]; 58% (C-EPI) and 8% (C-ADP) for platelet function disorders (PFDs); and the sensitivity of BT was 29% (VWD) and 33% (PFD). C-EPI CT was also prolonged in about 20% of patients with abnormalities of coagulation or fibrinolysis. Only the C-EPI CT was significantly associated with the levels of severity of the patients' bleeding scores.Conclusions: BT and C-EPI are insufficiently sensitive to be recommended as hemostasis screening tests. The C-ADP cartridge, which is sensitive to VWD only, might prove useful in further diagnostic workup of defects of primary hemostasis. The association of C-EPI CT with the severity of bleeding symptoms as a useful predictor of risk of bleeding in clinical practise should be tested in properly designed studies.

Usefulness of PFA-100 (R) testing in the diagnostic screening of patients with suspected abnormalities of hemostasis: comparison with the bleeding time / G. Podda, P. Bucciarelli, F. Lussana, A. Lecchi, M. Cattaneo. - In: JOURNAL OF THROMBOSIS AND HAEMOSTASIS. - ISSN 1538-7933. - 5:12(2007 Dec), pp. 2393-2398.

Usefulness of PFA-100 (R) testing in the diagnostic screening of patients with suspected abnormalities of hemostasis: comparison with the bleeding time

G. Podda
Primo
;
P. Bucciarelli
Secondo
;
F. Lussana;A. Lecchi
Penultimo
;
M. Cattaneo
Ultimo
2007

Abstract

Background: Global tests of hemostasis that are used to screen patients with clinical suspicion of bleeding disorders should help the physician to identify the phase of the hemostatic system that is abnormal and guide further diagnostic workup.Patients and methods: We compared the performance of Platelet Function Analyzer-100 (PFA-100((R))) closure time (CT) with bleeding time (BT), both of which are screening tests for primary hemostasis, in the diagnostic workup of 128 consecutive patients who were screened for bleeding disorders. The sensitivities of BT and PFA-100 CT for known defects of hemostasis were evaluated; in addition, we calculated their correlation with the levels of severity of the bleeding symptoms, which were recorded using a standardized questionnaire.Results: The sensitivity of PFA-100 testing was 71% for von Willebrand disease (VWD) [with both collagen-adenosine diphosphate (C-ADP) and collagen-epinephrine (C-EPI) cartridges]; 58% (C-EPI) and 8% (C-ADP) for platelet function disorders (PFDs); and the sensitivity of BT was 29% (VWD) and 33% (PFD). C-EPI CT was also prolonged in about 20% of patients with abnormalities of coagulation or fibrinolysis. Only the C-EPI CT was significantly associated with the levels of severity of the patients' bleeding scores.Conclusions: BT and C-EPI are insufficiently sensitive to be recommended as hemostasis screening tests. The C-ADP cartridge, which is sensitive to VWD only, might prove useful in further diagnostic workup of defects of primary hemostasis. The association of C-EPI CT with the severity of bleeding symptoms as a useful predictor of risk of bleeding in clinical practise should be tested in properly designed studies.
bleeding time; PFA-100; platelet function disorders; von Willebrand disease
Settore MED/09 - Medicina Interna
dic-2007
Article (author)
File in questo prodotto:
File Dimensione Formato  
PODDA_et_al-2007-Journal_of_Thrombosis_and_Haemostasis.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 173.94 kB
Formato Adobe PDF
173.94 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/196886
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 94
  • ???jsp.display-item.citation.isi??? 83
social impact