Due to its liver toxicity, the medicinal use of germander (Teucrium chamaedrys L.) was banned in some countries. Nevertheless, alcoholic extracts are still permitted as flavour ingredients since they are fundamental in providing a bitter aromatic taste. Teucrin A represents the substance of major concern regarding the potential toxicity of germander. Hence, teucrin A represents the best analytical and toxicological marker of alcoholic extracts of T. chamaedrys. A sensitive high-performance liquid chromatography method to detect teucrin A in beverages is reported. Teucrin A was prepared by isolation firom the plant extract using column chromatography and crystallization. The identity and purity (99%) were established by melting point, nuclear magnetic resonance and liquid chromatography-mass spectrometry. The high-performance liquid chromatography procedure was validated and its intra- and interday performance was established (relative standard deviation ≤ 13% and error ≤ 10%). In-house validation was carried out by analysing samples of beverages not containing T. chamaedrys spiked with a range of concentrations of teucrin A. The limit of detection was 0.1 ppm and the limit of quantification was 0.3 ppm. Teucrin A accounted for about 70% of the neo-clerodane diterpenoids found in the total extract of a specimen of T. chamaedrys. The content (± standard deviation) in 18 batches of different geographical origin was 2338 ± 740 ppm, per cent coefficient of variation = 32, minimum-maximum = 999-3445 ppm. The mean level of teucrin A in 10 bottles of the same brand was 6.1 ± 0.8 ppm, per cent coefficient of variation = 12. In 10 different brands found on the Italian market, the content of teucrin A ranged from not detectable to 10 ppm.

Analysis by high-performance liquid chromatography of teucrin A in beverages flavoured with an extract of Teucrium chamaedrys L / E. Bosisio, F. Giavarini, M. Dell'Agli, G. Galli, C. L. Galli. - In: FOOD ADDITIVES AND CONTAMINANTS. - ISSN 0265-203X. - 21:5(2004 May), pp. 407-414. [10.1080/02652030410001670157]

Analysis by high-performance liquid chromatography of teucrin A in beverages flavoured with an extract of Teucrium chamaedrys L.

E. Bosisio
Primo
;
F. Giavarini
Secondo
;
M. Dell'Agli;G. Galli
Penultimo
;
C.L. Galli
Ultimo
2004

Abstract

Due to its liver toxicity, the medicinal use of germander (Teucrium chamaedrys L.) was banned in some countries. Nevertheless, alcoholic extracts are still permitted as flavour ingredients since they are fundamental in providing a bitter aromatic taste. Teucrin A represents the substance of major concern regarding the potential toxicity of germander. Hence, teucrin A represents the best analytical and toxicological marker of alcoholic extracts of T. chamaedrys. A sensitive high-performance liquid chromatography method to detect teucrin A in beverages is reported. Teucrin A was prepared by isolation firom the plant extract using column chromatography and crystallization. The identity and purity (99%) were established by melting point, nuclear magnetic resonance and liquid chromatography-mass spectrometry. The high-performance liquid chromatography procedure was validated and its intra- and interday performance was established (relative standard deviation ≤ 13% and error ≤ 10%). In-house validation was carried out by analysing samples of beverages not containing T. chamaedrys spiked with a range of concentrations of teucrin A. The limit of detection was 0.1 ppm and the limit of quantification was 0.3 ppm. Teucrin A accounted for about 70% of the neo-clerodane diterpenoids found in the total extract of a specimen of T. chamaedrys. The content (± standard deviation) in 18 batches of different geographical origin was 2338 ± 740 ppm, per cent coefficient of variation = 32, minimum-maximum = 999-3445 ppm. The mean level of teucrin A in 10 bottles of the same brand was 6.1 ± 0.8 ppm, per cent coefficient of variation = 12. In 10 different brands found on the Italian market, the content of teucrin A ranged from not detectable to 10 ppm.
Bitter alcoholic beverages; Germander; High-performance liquid chromatography (HPLC) method; Teucrin A
Settore BIO/15 - Biologia Farmaceutica
Settore BIO/14 - Farmacologia
mag-2004
http://www.informaworld.com/smpp/ftinterface~content=a713599750~fulltext=713240930
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/28225
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 17
social impact