Spectral and cross-spectral analysis of R-R interval and systolic arterial pressure (SAP) spontaneous fluctuations have been proposed for noninvasive evaluation of baroreflex sensitivity (BRS). However, results are not in good agreement with clinical measurements. In this study, a bivariate parametric autoregressive model with exogenous input (ARXAR model), able to divide the R-R variability into SAP-related and -unrelated parts, was used to quantify the gain (alpha(ARXAR)) of the baroreflex regulatory mechanism. For performance assessing, two traditional noninvasive methods based on frequency domain analysis [spectral, baroreflex gain by autogressive model (alpha(AR)); cross-spectral, baroreflex gain by bivariate autoregressive model (alpha(2AR))] and one based on the time domain [baroreflex gain by sequence analysis (alpha(SEQ))] were considered and compared with the baroreflex gain by phenylephrine test (alpha(PHE)). The BRS evaluation was performed on 30 patients (61 +/- 10 yr) with recent (10 +/- 3 days) myocardial infarction. The ARXAR model allowed dividing the R-R variability (950 +/- 1,099 ms(2)) into SAP-related (256 +/- 418 ms(2)) and SAP-unrelated (694 +/- 728 ms(2)) parts. alpha(AR) (12.2 +/- 6.1 ms/mmHg) and alpha(2AR) (8.9 +/- 5.6 ms/mmHg) as well as alpha(SEQ) (12.6 +/- 7.1 ms/mmHg) overestimated BRS assessed by alpha(PHE) (6.4 +/- 4.7 ms/mmHg), whereas the ARXAR index gave a comparable value (alpha(ARXAR) = 5.4 +/- 3.3 ms/mmHg). All noninvasive methods were significantly correlated to alpha(PHE) (alpha(ARXAR) and alpha(SEQ) were more correlated than the other indexes). Thus the baroreflex gain obtained describing the causal dependence of R-R interval on SAP showed a good agreement with alpha(PHE) and may provide additional information regarding the gain estimation in the frequency domain.

Causal linear parametric model for baroreflex gain assessment in patients with recent myocardial infarction / G. Nollo, A. Porta, L. Faes, M. Del Greco, M. Disertori, F. Ravelli. - In: AMERICAN JOURNAL OF PHYSIOLOGY. HEART AND CIRCULATORY PHYSIOLOGY. - ISSN 0363-6135. - 280:4(2001), pp. H1830-H1839.

Causal linear parametric model for baroreflex gain assessment in patients with recent myocardial infarction

A. Porta
Secondo
;
2001

Abstract

Spectral and cross-spectral analysis of R-R interval and systolic arterial pressure (SAP) spontaneous fluctuations have been proposed for noninvasive evaluation of baroreflex sensitivity (BRS). However, results are not in good agreement with clinical measurements. In this study, a bivariate parametric autoregressive model with exogenous input (ARXAR model), able to divide the R-R variability into SAP-related and -unrelated parts, was used to quantify the gain (alpha(ARXAR)) of the baroreflex regulatory mechanism. For performance assessing, two traditional noninvasive methods based on frequency domain analysis [spectral, baroreflex gain by autogressive model (alpha(AR)); cross-spectral, baroreflex gain by bivariate autoregressive model (alpha(2AR))] and one based on the time domain [baroreflex gain by sequence analysis (alpha(SEQ))] were considered and compared with the baroreflex gain by phenylephrine test (alpha(PHE)). The BRS evaluation was performed on 30 patients (61 +/- 10 yr) with recent (10 +/- 3 days) myocardial infarction. The ARXAR model allowed dividing the R-R variability (950 +/- 1,099 ms(2)) into SAP-related (256 +/- 418 ms(2)) and SAP-unrelated (694 +/- 728 ms(2)) parts. alpha(AR) (12.2 +/- 6.1 ms/mmHg) and alpha(2AR) (8.9 +/- 5.6 ms/mmHg) as well as alpha(SEQ) (12.6 +/- 7.1 ms/mmHg) overestimated BRS assessed by alpha(PHE) (6.4 +/- 4.7 ms/mmHg), whereas the ARXAR index gave a comparable value (alpha(ARXAR) = 5.4 +/- 3.3 ms/mmHg). All noninvasive methods were significantly correlated to alpha(PHE) (alpha(ARXAR) and alpha(SEQ) were more correlated than the other indexes). Thus the baroreflex gain obtained describing the causal dependence of R-R interval on SAP showed a good agreement with alpha(PHE) and may provide additional information regarding the gain estimation in the frequency domain.
Autoregressive models; Baroreflex sensitivity; Phenylephrine; R-R-SAP transfer function; Spectral analysis
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
Settore MED/09 - Medicina Interna
2001
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/24185
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 37
social impact