Background: Angiography and fluoroscopy are the standard methods to guide transcatheter occlusion of patent ductus arteriosus (PDA). The use of iodinated contrast agents and radiation exposure pose risks of animals and staff. Objectives: To assess feasibility of transesophageal echocardiography (TEE) for device size selection and procedure monitoring for PDA occlusion with a duct occluder (DO) without the use of angiography. Animals: Eighty client-owned dogs with left-to-right PDA. Methods: Prospective study. Dogs with left-to-right PDA undergoing transcatheter occlusion were included. Procedures were performed without angiography and device size selection was based on TEE measurements. Procedures were monitored with simultaneous TEE and fluoroscopy and both methods were compared. Visualization of the ductus and dimensions obtained by TEE and transthoracic echocardiography (TTE) were compared. Results: Complete PDA occlusion was achieved in 79/80 cases. TEE was consistently superior to TTE for PDA visualization and the latter showed higher values for ductal dimensions when compared to the former. TEE provided adequate procedure monitoring in 73 cases (91%). Fluoroscopy exposure time (2.77 ± 1.2 minutes (mean, SD)) was lower than previously reported for the same procedure. Conclusions and Clinical Importance: TEE is a useful and efficient tool for device size selection and can be used for procedure monitoring in most cases. Fluoroscopy exposure time can be reduced and the use of contrast agents can be avoided. However, fluoroscopy is required in a minority of cases when TEE monitoring is not feasible or incomplete and should be available for this procedure.

Transesophageal echocardiography guided patent ductus arteriosus occlusion with a duct cccluder / J. Silva, O. Domenech, A. Mavropoulou, P. Oliveira, C. Locatelli, C. Bussadori. - In: JOURNAL OF VETERINARY INTERNAL MEDICINE. - ISSN 0891-6640. - 27:6(2013 Oct 01), pp. 1463-1470. [Epub ahead of print]

Transesophageal echocardiography guided patent ductus arteriosus occlusion with a duct cccluder

C. Locatelli;C. Bussadori
2013

Abstract

Background: Angiography and fluoroscopy are the standard methods to guide transcatheter occlusion of patent ductus arteriosus (PDA). The use of iodinated contrast agents and radiation exposure pose risks of animals and staff. Objectives: To assess feasibility of transesophageal echocardiography (TEE) for device size selection and procedure monitoring for PDA occlusion with a duct occluder (DO) without the use of angiography. Animals: Eighty client-owned dogs with left-to-right PDA. Methods: Prospective study. Dogs with left-to-right PDA undergoing transcatheter occlusion were included. Procedures were performed without angiography and device size selection was based on TEE measurements. Procedures were monitored with simultaneous TEE and fluoroscopy and both methods were compared. Visualization of the ductus and dimensions obtained by TEE and transthoracic echocardiography (TTE) were compared. Results: Complete PDA occlusion was achieved in 79/80 cases. TEE was consistently superior to TTE for PDA visualization and the latter showed higher values for ductal dimensions when compared to the former. TEE provided adequate procedure monitoring in 73 cases (91%). Fluoroscopy exposure time (2.77 ± 1.2 minutes (mean, SD)) was lower than previously reported for the same procedure. Conclusions and Clinical Importance: TEE is a useful and efficient tool for device size selection and can be used for procedure monitoring in most cases. Fluoroscopy exposure time can be reduced and the use of contrast agents can be avoided. However, fluoroscopy is required in a minority of cases when TEE monitoring is not feasible or incomplete and should be available for this procedure.
Canine; Congenital heart disease; Fluoroscopy; Interventional
Settore VET/08 - Clinica Medica Veterinaria
1-ott-2013
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/226894
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact