Purpose: The aim of this prospective study was to assess long-term clinical outcomes and peri-implant bone level changes around oxidized implants supporting partial fixed rehabilitations. Materials and Methods: Twenty-two partially edentulous patients were included in the study. A total of 33 fixed rehabilitations were placed, supported by 54 titanium implants with oxidized microtextured surface. Prostheses were delivered after 3 and 6 months of implant placement in the mandible and maxilla, respectively. Patients were scheduled for follow-up at 6 and 12 months and then yearly. At each follow-up, plaque level and bleeding scores were assessed and periapical radiographs were taken. The main outcomes were prosthesis success, implant survival, implant success, and marginal bone level change. Results: Three patients were excluded from the study because they did not attend the 1-year follow-up. Nineteen patients, accounting for 49 implants, were followed for at least 6 years after prosthesis delivery. The mean follow-up duration was 81.8 months (range 75-96 months). One mandibular single-tooth implant failed after 1 year in a smoker woman. Cumulative implant survival and success at 6 years were 98.0% and 95.9%, respectively. Prosthesis success was 96.7%. The mean peri-implant bone loss at 6 years was 0.76 ± 0.47 mm. Not significantly (p = .75) greater bone loss was found in the maxilla (0.78 ± 0.14 mm, n = 19) as compared with the mandible (0.74 ± 0.59 mm, n = 30). In the maxilla, bone loss was significantly greater around implants supporting partial prostheses as compared with single-tooth implants (p = .03). Full patient satisfaction was reported. Conclusion: Implants with oxidized microtextured surface may achieve excellent long-term clinical outcomes in the rehabilitation of partial edentulism.

Evaluation of clinical outcomes and bone loss around titanium implants with oxidized surface : six-year follow-up results from a prospective case series study / L. Francetti, F. Azzola, S. Corbella, S. Taschieri, M. Del Fabbro. - In: CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH. - ISSN 1523-0899. - 16:1(2014 Feb), pp. 81-88. [10.1111/j.1708-8208.2012.00466.x]

Evaluation of clinical outcomes and bone loss around titanium implants with oxidized surface : six-year follow-up results from a prospective case series study

L. Francetti
Primo
;
S. Corbella;S. Taschieri
Penultimo
;
M. Del Fabbro
Ultimo
2014

Abstract

Purpose: The aim of this prospective study was to assess long-term clinical outcomes and peri-implant bone level changes around oxidized implants supporting partial fixed rehabilitations. Materials and Methods: Twenty-two partially edentulous patients were included in the study. A total of 33 fixed rehabilitations were placed, supported by 54 titanium implants with oxidized microtextured surface. Prostheses were delivered after 3 and 6 months of implant placement in the mandible and maxilla, respectively. Patients were scheduled for follow-up at 6 and 12 months and then yearly. At each follow-up, plaque level and bleeding scores were assessed and periapical radiographs were taken. The main outcomes were prosthesis success, implant survival, implant success, and marginal bone level change. Results: Three patients were excluded from the study because they did not attend the 1-year follow-up. Nineteen patients, accounting for 49 implants, were followed for at least 6 years after prosthesis delivery. The mean follow-up duration was 81.8 months (range 75-96 months). One mandibular single-tooth implant failed after 1 year in a smoker woman. Cumulative implant survival and success at 6 years were 98.0% and 95.9%, respectively. Prosthesis success was 96.7%. The mean peri-implant bone loss at 6 years was 0.76 ± 0.47 mm. Not significantly (p = .75) greater bone loss was found in the maxilla (0.78 ± 0.14 mm, n = 19) as compared with the mandible (0.74 ± 0.59 mm, n = 30). In the maxilla, bone loss was significantly greater around implants supporting partial prostheses as compared with single-tooth implants (p = .03). Full patient satisfaction was reported. Conclusion: Implants with oxidized microtextured surface may achieve excellent long-term clinical outcomes in the rehabilitation of partial edentulism.
bone loss; dental implants; mandible; maxilla; oxidized surface; partial edentulism
Settore MED/28 - Malattie Odontostomatologiche
feb-2014
1-giu-2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
Francetti_et_al-2014-Clinical_Implant_Dentistry_and_Related_Research.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 399.26 kB
Formato Adobe PDF
399.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/194547
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 21
social impact