A study was carried out in order to determine the feasibility and reproducibility of a direct plethysmographic assessment of unstimulated forearm arterial compliance (FAC) in hypercholesterolaemic and normocholesterolaemic subjects. Simultaneous recordings of forearm pulse volume and blood pressure over the whole cardiac cycle are used to establish the pulse volume-blood pressure relationship. FAC was measured on-line by computing the ratio of dV/dP. The area under the curve (FAC(AUC)) of FAC/blood-pressure curve was determined in a standard range of blood pressure (70-130 mmHg). The method was validated by demonstrating its capacity to detect changes in FAC(AUC) induced by nitrate and by muscarinic stimuli. The results show a reduced FAC(AUC) in hypercholesterolaemic patients vs. controls (2.28 +/- 0.8 x 10(-3) vs. 4.12 +/- 1.06 x 10(-3) (mL 100 mL-1 forearm mmHg-1) mmHg; P = 0.0001). The method appears to be highly sensitive to nitrate and muscarinic stimuli. The new technique provides a potentially useful tool to detect and monitor in vivo, without stimulating arterial dilatation, e.g. by acetylcholine infusion, the functional arterial changes in subjects with a major risk factor for arterial disease as well as the effects of dietary/drug treatments.

Non-invasive assessment of unstimulated forearm arterial compliance in human subjects. Impaired vasoreactivity in hypercholesterolaemia / D. Baldassarre, G. Gianfranceschi, F. Pazzucconi, C. R. Sirtori. - In: EUROPEAN JOURNAL OF CLINICAL INVESTIGATION. - ISSN 0014-2972. - 25:11(1995 Nov), pp. 859-866.

Non-invasive assessment of unstimulated forearm arterial compliance in human subjects. Impaired vasoreactivity in hypercholesterolaemia

D. Baldassarre
Primo
;
F. Pazzucconi
Penultimo
;
C. R. Sirtori
Ultimo
1995

Abstract

A study was carried out in order to determine the feasibility and reproducibility of a direct plethysmographic assessment of unstimulated forearm arterial compliance (FAC) in hypercholesterolaemic and normocholesterolaemic subjects. Simultaneous recordings of forearm pulse volume and blood pressure over the whole cardiac cycle are used to establish the pulse volume-blood pressure relationship. FAC was measured on-line by computing the ratio of dV/dP. The area under the curve (FAC(AUC)) of FAC/blood-pressure curve was determined in a standard range of blood pressure (70-130 mmHg). The method was validated by demonstrating its capacity to detect changes in FAC(AUC) induced by nitrate and by muscarinic stimuli. The results show a reduced FAC(AUC) in hypercholesterolaemic patients vs. controls (2.28 +/- 0.8 x 10(-3) vs. 4.12 +/- 1.06 x 10(-3) (mL 100 mL-1 forearm mmHg-1) mmHg; P = 0.0001). The method appears to be highly sensitive to nitrate and muscarinic stimuli. The new technique provides a potentially useful tool to detect and monitor in vivo, without stimulating arterial dilatation, e.g. by acetylcholine infusion, the functional arterial changes in subjects with a major risk factor for arterial disease as well as the effects of dietary/drug treatments.
Vasodilator Agents; Reproducibility of Results; Blood Pressure; Arteries; Humans; Compliance; Hemodynamics; Nitroglycerin; Acetylcholine; Middle Aged; Plethysmography; Administration, Sublingual; Hypercholesterolemia; Female; Forearm; Male
Settore BIO/14 - Farmacologia
nov-1995
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/191721
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact