The intermethod variabilities of control materials and patient blood samples for the measurement of glycohemoglobin were compared. Sets of 50 blood samples and 15 control materials were analyzed by HPLC and affinity and immunochemical methods. For each pair of methods, the distances of the materials from the regression line of patient blood results (expressed as normalized residuals) were calculated. Only two of 15 controls had normalized residuals exceeding 3 standard deviations from the regression line. Total hemoglobin (Hb) content, Hb derivatives, and cellulose acetate electrophoresis demonstrated that only a minority of controls could be considered similar to patients' blood samples. We selected Menarini's and our home-prepared controls to simulate calibration of the different techniques by these materials. Intermethod calibration succeeded mostly in harmonizing results obtained by HPLC methods. On the contrary, calibration of the immunochemical techniques (Boehringer and Roche) did not improve intermethod agreement to a clinically useful level.

Commutability of control materials in glycohemoglobin determinations / A. Mosca, R. Paleari, A. Madè, C. Ferrero, M. Locatelli, F. Ceriotti. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 44:3(1998), pp. 632-638.

Commutability of control materials in glycohemoglobin determinations

A. Mosca
Primo
;
R. Paleari
Secondo
;
1998

Abstract

The intermethod variabilities of control materials and patient blood samples for the measurement of glycohemoglobin were compared. Sets of 50 blood samples and 15 control materials were analyzed by HPLC and affinity and immunochemical methods. For each pair of methods, the distances of the materials from the regression line of patient blood results (expressed as normalized residuals) were calculated. Only two of 15 controls had normalized residuals exceeding 3 standard deviations from the regression line. Total hemoglobin (Hb) content, Hb derivatives, and cellulose acetate electrophoresis demonstrated that only a minority of controls could be considered similar to patients' blood samples. We selected Menarini's and our home-prepared controls to simulate calibration of the different techniques by these materials. Intermethod calibration succeeded mostly in harmonizing results obtained by HPLC methods. On the contrary, calibration of the immunochemical techniques (Boehringer and Roche) did not improve intermethod agreement to a clinically useful level.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
1998
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/190326
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact