An underlying assumption of the WHO orthogonal regression model for prothrombin time standardisation is that a single line describes the relationship between PT of abnormal and normal plasmas. The aim was to evaluate Tomenson's correction for lack of coincidence using the model of the ECAA human reagent with lyophilized plasma calibrations. Local ISI calibrations using ECAA lyophilized normal and abnormal plasmas were performed on coagulometers with the ECAA human thromboplastin. They gave a high incidence of non-linearity of the two calibration slopes. The mean percentage deviation from assigned values of the target coumarin plasmas coagulometer INR at 45 centres before local ISI correction was 16.6% and 11.9% respectively in two studies. After local ISI calibration, the unsigned deviation was reduced to 5.54% and 6.61% respectively. Tomenson's correction for non-linearity further reduced the mean deviation to 3.08% and 2.96% respectively in the two studies demonstrating the value of the procedure.

Correction for lack of coincidence of normal and abnormal calibration slopes in ISI determination / L. Poller, A.M.H.P. van den Besselaar, J. Jespersen, A. Tripodi, D. Houghton. - In: THROMBOSIS AND HAEMOSTASIS. - ISSN 0340-6245. - 81:6(1999), pp. 935-939.

Correction for lack of coincidence of normal and abnormal calibration slopes in ISI determination

A. Tripodi
Penultimo
;
1999

Abstract

An underlying assumption of the WHO orthogonal regression model for prothrombin time standardisation is that a single line describes the relationship between PT of abnormal and normal plasmas. The aim was to evaluate Tomenson's correction for lack of coincidence using the model of the ECAA human reagent with lyophilized plasma calibrations. Local ISI calibrations using ECAA lyophilized normal and abnormal plasmas were performed on coagulometers with the ECAA human thromboplastin. They gave a high incidence of non-linearity of the two calibration slopes. The mean percentage deviation from assigned values of the target coumarin plasmas coagulometer INR at 45 centres before local ISI correction was 16.6% and 11.9% respectively in two studies. After local ISI calibration, the unsigned deviation was reduced to 5.54% and 6.61% respectively. Tomenson's correction for non-linearity further reduced the mean deviation to 3.08% and 2.96% respectively in the two studies demonstrating the value of the procedure.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
1999
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189825
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact