The volume/pressure (V/P) curve of the total respiratory system in paralysed patients is drawn assuming that volume changes of the respiratory system (delta V resp) equals volume displacement of the measuring apparatus (delta V syr), usually a supersyringe. However, in 93 VP curves we found that O2 removed from the lung-syringe system during the procedure (proportional to the time) largely exceeds the CO2 added to the lung-syringe system (delta V gas). This results in a net loss of volume from the system (delta V resp less than delta V-syr). Deflation compliance, hysteresis area and ratio are significantly affected by this phenomenon. Inflation compliance is less influenced by delta V gas, partially compensated by the intrapulmonary gas expansion due to the temperature changes. We conclude that the parameters computed on the deflation limb of V/P curve are misleading if proper correction of the volume scale is not introduced.

Volume/pressure curve of total respiratory system in paralysed patients: artefacts and correction factors / L. Gattinoni, D. Mascheroni, E. Basilico, G. Foti, A. Pesenti, L. Avalli. - In: INTENSIVE CARE MEDICINE. - ISSN 0342-4642. - 13:1(1987), pp. 19-25-25. [10.1007/BF00263552]

Volume/pressure curve of total respiratory system in paralysed patients: artefacts and correction factors

L. Gattinoni;A. Pesenti;
1987

Abstract

The volume/pressure (V/P) curve of the total respiratory system in paralysed patients is drawn assuming that volume changes of the respiratory system (delta V resp) equals volume displacement of the measuring apparatus (delta V syr), usually a supersyringe. However, in 93 VP curves we found that O2 removed from the lung-syringe system during the procedure (proportional to the time) largely exceeds the CO2 added to the lung-syringe system (delta V gas). This results in a net loss of volume from the system (delta V resp less than delta V-syr). Deflation compliance, hysteresis area and ratio are significantly affected by this phenomenon. Inflation compliance is less influenced by delta V gas, partially compensated by the intrapulmonary gas expansion due to the temperature changes. We conclude that the parameters computed on the deflation limb of V/P curve are misleading if proper correction of the volume scale is not introduced.
Acute respiratory failure; Pulmonary mechanics; Volume pressure curve
Settore MED/41 - Anestesiologia
1987
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/185560
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 79
  • ???jsp.display-item.citation.isi??? 63
social impact