A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fluoroaniline (FDNDEA) at 100-degrees-C for 20 min. The DNDEA-hydroxyproline adduct was separated on an Ultrasphere ODS column with a mobile phase of acetate buffer (containing triethylamine, 6 mL/L, pH 4.3) and acetonitrile (80/20, by vol), and was detected at 360 nm. A single run took 18 min with a hydroxyproline retention time of 7.3 min. The assay showed a linear response to hydroxyproline concentrations from 5 to 100 mg/L with a detection limit of 0.8 ng injected, corresponding to 2 mg/L in urine. Mean (SD) analytical recovery was 94.2 (13)% and 104 (9)% at 10 and 50 mg/L, respectively. Within-run and between-run CVs (n = 10) were 3.74% and 4.33%, respectively, for 25 mg/L. Results for samples (n = 50) analyzed by HPLC (y) vs ion-exchange chromatography with postcolumn ninhydrin reaction (x) correlated well: y = 0.98x + 1.02 (r = 0.985, S(xy) = 3.13). In another comparison, involving 173 samples, a colorimetric procedure (Hypronosticon(R), x) gave slightly higher values than the HPLC method (y): y = 0.83x + 2.21 (r = 0.937, S(xy) = 4.6).

TOTAL URINARY HYDROXYPROLINE DETERMINED WITH RAPID AND SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY / R. PARONI, E. DEVECCHI, I. FERMO, C. ARCELLONI, L. DIOMEDE, F. MAGNI, P.A. BONINI. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 38:3(1992 Mar), pp. 407-411.

TOTAL URINARY HYDROXYPROLINE DETERMINED WITH RAPID AND SIMPLE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

R. PARONI
Primo
;
1992

Abstract

A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fluoroaniline (FDNDEA) at 100-degrees-C for 20 min. The DNDEA-hydroxyproline adduct was separated on an Ultrasphere ODS column with a mobile phase of acetate buffer (containing triethylamine, 6 mL/L, pH 4.3) and acetonitrile (80/20, by vol), and was detected at 360 nm. A single run took 18 min with a hydroxyproline retention time of 7.3 min. The assay showed a linear response to hydroxyproline concentrations from 5 to 100 mg/L with a detection limit of 0.8 ng injected, corresponding to 2 mg/L in urine. Mean (SD) analytical recovery was 94.2 (13)% and 104 (9)% at 10 and 50 mg/L, respectively. Within-run and between-run CVs (n = 10) were 3.74% and 4.33%, respectively, for 25 mg/L. Results for samples (n = 50) analyzed by HPLC (y) vs ion-exchange chromatography with postcolumn ninhydrin reaction (x) correlated well: y = 0.98x + 1.02 (r = 0.985, S(xy) = 3.13). In another comparison, involving 173 samples, a colorimetric procedure (Hypronosticon(R), x) gave slightly higher values than the HPLC method (y): y = 0.83x + 2.21 (r = 0.937, S(xy) = 4.6).
CHROMATOGRAPHY, REVERSED-PHASE; BONE PROTEIN; AMINO ACIDS; PRE-COLUMN DERIVATIZATION; AUTOMATED-ANALYSIS; BLOOD-PLASMA; EXCRETION; PROLINE; ACIDS
Settore BIO/10 - Biochimica
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
mar-1992
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/183535
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 19
social impact