We compared single motor unit and surface EMG responses in the active right tibialis anterior following anodal electrical or magnetic stimulation of the motor cortex over the vertex. Magnetic stimulation used a monophasic current pulse through a circular coil centred 3 cm anterior to the vertex. Lowest threshold magnetic stimulation occurred when the current in the coil flowed from the left to the right side at the posterior rim of the coil. Such stimulation produced single unit and surface EMG responses which had the same latency as those produced by anodal electric stimulation. If the direction of the magnetic stimulating current was reversed, response latencies became more variable from unit to unit, and on average they occurred 1.0 +/- 0.5 msec later. In single motor units anodal and magnetic post-stimulus time histogram (PSTH) peaks had the same duration. This was similar to the duration of the PSTH peaks produced by a single low intensity stimulus given to the common peroneal nerve. We conclude that magnetic stimulation can produce direct activation of corticospinal neurones to the tibialis anterior if the direction of induced current flow is optimal. This projection is likely to be either monosynaptic or oligosynaptic.

TRANSCRANIAL ELECTRIC AND MAGNETIC STIMULATION OF THE LEG AREA OF THE HUMAN MOTOR CORTEX - SINGLE MOTOR UNIT AND SURFACE EMG RESPONSES IN THE TIBIALIS ANTERIOR MUSCLE / A. Priori, L. Bertolasi, D. Dressler, J. Rothwell, B. Day, P. Thompson, C. Marsden. - In: ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY. - ISSN 0013-4694. - 89:2(1993 Apr), pp. 131-137. [10.1016/0168-5597(93)90095-7]

TRANSCRANIAL ELECTRIC AND MAGNETIC STIMULATION OF THE LEG AREA OF THE HUMAN MOTOR CORTEX - SINGLE MOTOR UNIT AND SURFACE EMG RESPONSES IN THE TIBIALIS ANTERIOR MUSCLE

A. Priori
Primo
;
1993

Abstract

We compared single motor unit and surface EMG responses in the active right tibialis anterior following anodal electrical or magnetic stimulation of the motor cortex over the vertex. Magnetic stimulation used a monophasic current pulse through a circular coil centred 3 cm anterior to the vertex. Lowest threshold magnetic stimulation occurred when the current in the coil flowed from the left to the right side at the posterior rim of the coil. Such stimulation produced single unit and surface EMG responses which had the same latency as those produced by anodal electric stimulation. If the direction of the magnetic stimulating current was reversed, response latencies became more variable from unit to unit, and on average they occurred 1.0 +/- 0.5 msec later. In single motor units anodal and magnetic post-stimulus time histogram (PSTH) peaks had the same duration. This was similar to the duration of the PSTH peaks produced by a single low intensity stimulus given to the common peroneal nerve. We conclude that magnetic stimulation can produce direct activation of corticospinal neurones to the tibialis anterior if the direction of induced current flow is optimal. This projection is likely to be either monosynaptic or oligosynaptic.
TRANSCRANIAL MAGNETIC STIMULATION; MOTOR CORTEX; TIBIALIS ANTERIOR; TRANSCRANIAL ELECTRIC STIMULATION
Settore MED/26 - Neurologia
apr-1993
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/182910
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 79
  • ???jsp.display-item.citation.isi??? 75
social impact