Aims: This research focused on the effects of low electric current ( LEC) on the cell viability and metabolic activity of Escherichia coli and Bacillus cereus. Methods and Results: Different LEC intensities at fixed amperage were applied, employing either graphite or copper electrode pairs, and the effects were determined by conventional cultural methods and bioindicators. On E. coli, the LEC with graphite electrodes at 5 and 10 mA led to no significant variation, but at 20 and 40 mA there was increasing inhibition of both the enzymatic activities and growth, and a reduction in ATP content. On B. cereus, similar experiments at the lower amperages did not have any inhibitor effects, however, the 40 mA current stimulated growth, ATP content and some enzymatic activities. The LEC treatment using copper electrodes caused, already at 5 mA, inhibition of bacterial growth and metabolic and enzymatic activities in both E. coli and B. cereus. Conclusions: On the basis of the obtained results using different amperages and electrodes, we can conclude that E. coli seem to be more sensitive compared with B. cereus. Significance and Impact of the Study: The study increases the knowledge on LEC treatment effects on the pure bacterial cultures

Effects of low electric current (LEC) treatment on pure bacterial cultures / A. Valle, P. Abbruscato, P. Argenzio, G. Lustrato, G. Ranalli, C. Sorlini. - In: JOURNAL OF APPLIED MICROBIOLOGY. - ISSN 1364-5072. - 103:5(2007 Nov), pp. 1376-1385.

Effects of low electric current (LEC) treatment on pure bacterial cultures

C. Sorlini
Ultimo
2007

Abstract

Aims: This research focused on the effects of low electric current ( LEC) on the cell viability and metabolic activity of Escherichia coli and Bacillus cereus. Methods and Results: Different LEC intensities at fixed amperage were applied, employing either graphite or copper electrode pairs, and the effects were determined by conventional cultural methods and bioindicators. On E. coli, the LEC with graphite electrodes at 5 and 10 mA led to no significant variation, but at 20 and 40 mA there was increasing inhibition of both the enzymatic activities and growth, and a reduction in ATP content. On B. cereus, similar experiments at the lower amperages did not have any inhibitor effects, however, the 40 mA current stimulated growth, ATP content and some enzymatic activities. The LEC treatment using copper electrodes caused, already at 5 mA, inhibition of bacterial growth and metabolic and enzymatic activities in both E. coli and B. cereus. Conclusions: On the basis of the obtained results using different amperages and electrodes, we can conclude that E. coli seem to be more sensitive compared with B. cereus. Significance and Impact of the Study: The study increases the knowledge on LEC treatment effects on the pure bacterial cultures
Bacillus cereus; Escherichia coli; Graphite and copper electrodes; Low electric current
Settore AGR/16 - Microbiologia Agraria
nov-2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/180014
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 48
social impact