Oxygen equilibrium curves of fresh, normal human blood have been measured by new methods which allow the control of pH, pCO2, and 2,3-diphosphoglycerate and which yield higher accuracy at the extremes of saturation than was possible previously. The curve determined by these techniques lies slightly to the right of the standard curve of Roughton et al. (Roughton, F.J.W., Deland, E.C., Kernohan, J.C., and Severinghaus, J.W. (1972) in Oxygen Affinity of Hemoglobin and Red Cell Acid Base Status (Astrup, P., and Rørth, M., eds) pp. 73-83, Academic Press, New York). The greatest difference is at low oxygen saturation, probably owing to the fact that the latter data were obtained under conditions which would lead to depletion of cellular 2,3-diphosphoglycerate. The range of p50 (oxygen pressure at half-saturation) values for four normal subjects was 28.3 mm Hg to 29.0 mm Hg. Adair's stepwise oxygenation scheme has been used to analyze the curves with the result that a1 = 0.1514 X 10(-1) (+/- 10%) mm-1; a2 = 0.9723 X 10(-3) (+/- 8%) mm-2; a3 = 0.1703 X 10(-3) (+/- 50%) mm-3; a4 = 0.1671 X 10(-5) (+/- 2%) mm-4 for the best of four data sets. Because these constants are very sensitive to changes in the shape of the oxygenation curve, this analysis is much more useful than p50 measurements in the investigation of the various allosteric effectors of the function of hemoglobin within the red cell.

Oxygen equilibrium curve of normal human blood and its evaluation by Adair's equation / R.M. Winslow, M.L. Swenberg, R.L. Berger, R.I. Shrager, M. Luzzana, M. Samaja, L. Rossi-Bernardi. - In: THE JOURNAL OF BIOLOGICAL CHEMISTRY. - ISSN 0021-9258. - 252:7(1977 Apr 10), pp. 2331-2337.

Oxygen equilibrium curve of normal human blood and its evaluation by Adair's equation

M. Samaja
Penultimo
;
1977

Abstract

Oxygen equilibrium curves of fresh, normal human blood have been measured by new methods which allow the control of pH, pCO2, and 2,3-diphosphoglycerate and which yield higher accuracy at the extremes of saturation than was possible previously. The curve determined by these techniques lies slightly to the right of the standard curve of Roughton et al. (Roughton, F.J.W., Deland, E.C., Kernohan, J.C., and Severinghaus, J.W. (1972) in Oxygen Affinity of Hemoglobin and Red Cell Acid Base Status (Astrup, P., and Rørth, M., eds) pp. 73-83, Academic Press, New York). The greatest difference is at low oxygen saturation, probably owing to the fact that the latter data were obtained under conditions which would lead to depletion of cellular 2,3-diphosphoglycerate. The range of p50 (oxygen pressure at half-saturation) values for four normal subjects was 28.3 mm Hg to 29.0 mm Hg. Adair's stepwise oxygenation scheme has been used to analyze the curves with the result that a1 = 0.1514 X 10(-1) (+/- 10%) mm-1; a2 = 0.9723 X 10(-3) (+/- 8%) mm-2; a3 = 0.1703 X 10(-3) (+/- 50%) mm-3; a4 = 0.1671 X 10(-5) (+/- 2%) mm-4 for the best of four data sets. Because these constants are very sensitive to changes in the shape of the oxygenation curve, this analysis is much more useful than p50 measurements in the investigation of the various allosteric effectors of the function of hemoglobin within the red cell.
Settore BIO/10 - Biochimica
10-apr-1977
http://www.jbc.org/content/252/7/2331.long
Article (author)
File in questo prodotto:
File Dimensione Formato  
04-77JBC_OEC_Adair.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/175897
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 88
  • ???jsp.display-item.citation.isi??? ND
social impact