Objective: This study aimed to estimate the frequency and timing of washout in a series of pathologically proven benign mass-like breast lesions at dynamic magnetic resonance imaging. Methods: Institutional review board approval was obtained for this retrospective study. We evaluated enhancement kinetics of 33 pathologically confirmed benign breast lesions: fibroadenomas (n = 22), adenosis (n = 6), typical ductal hyperplasia (n = 2), fibroadenoma with ductal hyperplasia (n = 1), fibrosclerosis (n = 1), and inflammatory lesion (n = 1). Coronal 3-dimensional T1-weighted gradient-echo sequences were acquired before/after intravenous injection of 0.1 mmol/ kg gadoterate meglumine (time resolution, 111 seconds), 1 before and 5 after contrast injection. The time point at which the kinetic curve demonstrated a washout was recorded. Cumulative distribution of lesions showing washout was built. Paired comparisons of specificity for washout kinetics were performed using the McNemar test. Results: Of 33 lesions, washout was never observed in 20 (61%), whereas 13 (39%) showed washout during the study. Of these 13 lesions, only 1 (inflammatory mass) exhibited washout within the first 3 minutes (specificity, 97%), 9 within 6 minutes (specificity, 73%), and 13 within 8 minutes (specificity, 61%). Specificity of washout kinetics within 3 minutes (97%) was significantly larger than that from the sixth minute (73%) and thereafter (P < 0.016). Conclusions: A prolonged observation for dynamic breast magnetic resonance imaging may result in false-positive washout, especially after 6 minutes. Late washout should not be considered a reliable marker of malignancy. Copyright

Washout of mass-like benign breast lesions at dynamic magnetic resonance imaging / P. Tannaphai, R.M. Trimboli, L.A. Carbonaro, S. Viganò, G. Di Leo, F. Sardanelli. - In: JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY. - ISSN 0363-8715. - 36:3(2012), pp. 301-305. [10.1097/RCT.0b013e3182506c48]

Washout of mass-like benign breast lesions at dynamic magnetic resonance imaging

R.M. Trimboli
Secondo
;
L.A. Carbonaro;S. Vigano';F. Sardanelli
Ultimo
2012

Abstract

Objective: This study aimed to estimate the frequency and timing of washout in a series of pathologically proven benign mass-like breast lesions at dynamic magnetic resonance imaging. Methods: Institutional review board approval was obtained for this retrospective study. We evaluated enhancement kinetics of 33 pathologically confirmed benign breast lesions: fibroadenomas (n = 22), adenosis (n = 6), typical ductal hyperplasia (n = 2), fibroadenoma with ductal hyperplasia (n = 1), fibrosclerosis (n = 1), and inflammatory lesion (n = 1). Coronal 3-dimensional T1-weighted gradient-echo sequences were acquired before/after intravenous injection of 0.1 mmol/ kg gadoterate meglumine (time resolution, 111 seconds), 1 before and 5 after contrast injection. The time point at which the kinetic curve demonstrated a washout was recorded. Cumulative distribution of lesions showing washout was built. Paired comparisons of specificity for washout kinetics were performed using the McNemar test. Results: Of 33 lesions, washout was never observed in 20 (61%), whereas 13 (39%) showed washout during the study. Of these 13 lesions, only 1 (inflammatory mass) exhibited washout within the first 3 minutes (specificity, 97%), 9 within 6 minutes (specificity, 73%), and 13 within 8 minutes (specificity, 61%). Specificity of washout kinetics within 3 minutes (97%) was significantly larger than that from the sixth minute (73%) and thereafter (P < 0.016). Conclusions: A prolonged observation for dynamic breast magnetic resonance imaging may result in false-positive washout, especially after 6 minutes. Late washout should not be considered a reliable marker of malignancy. Copyright
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/174181
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact