Background. For coronary surgery we often use the radial artery (RA) instead of the saphenous vein, trying to exploit the advantages offered by this conduit. To eliminate the problems regarding alteration of upper-extremity function after RA procurement related to the standard conventional harvesting technique, we started using the less invasive harvesting technique with surprisingly good preliminary results. To compare the outcomes of open versus less invasive harvesting procedures, a prospective, nonrandomized study was developed by 2 centers. Methods. From January 2001 to March 2003, there were 87 consecutive patients in the less invasive radial artery harvesting (LIRAH) group and 90 patients in the conventional radial artery harvesting (CRAH) group. Patient characteristics and demographics were similar in the groups. Data collection was made to evaluate possible benefits of the LIRAH technique in terms of fewer forearm and hand complications, better aesthetics, and improved patient satisfaction. Results Between January 11, 2001, and March 30, 2003, 177 patients underwent either primary or redo coronary artery revascularizations with procurement of the RA for use as a conduit with the less invasive harvesting technique. The mean follow-up was 2 months. Four patients died, and overall mortality was 2.26%. One hundred seventy-three patients were successfully examined during the first postoperative control, 85 in the LIRAH group and 88 patients in the CRAH group. Objective and subjective data were collected from the consultant. The overall average age was 60.5 years (range, 40-77 years). In the LIRAH group, the mean overall incision length (when 2 incisions were necessary, both incision lengths were measured) was 5.6 cm (range, 4-10 cm), and the mean vessel length was 16 cm (range, 10-19 cm). Eighteen patients (20.6%) necessitated double incision. Mean harvesting time (from incision to skin closure) was 43.3 min (range, 25-70 min). Fourteen patients (16.4%) presented some kind of complication during the study. There were no cases with acute ischemia, bleeding, or re-exploration. Seventy-five patients (88.2%) found the cosmetic result excellent. Ten patients (11.8%) found it good, and none considered it mediocre. In the CRAH group, the mean incision length was 20 cm (range, 18-22 cm), and the mean vessel length was 18 cm (range, 17-20 cm ). Mean harvesting time (from incision to skin closure) was 30.8 min (range, 14-45 min). Thirty-four patients (38.6%) presented some kind of complication during the study. Three patients (3.5%) found the cosmetic result excellent. Forty-three (48.8%) found it good, and 42 (47.7%) considered it mediocre. Conclusions. A potential of fewer neurological forearm postoperative complications, better aesthetics, and improved patient satisfaction can be achieved by the LIRAH technique.

Less Invasive Radial Artery Harvesting : Two Years' Experience / D. Buklas, G. Gelpi, E. Neri, G. Babatasi, O. Lepage, C. Ivascau, S. Bichi, C. Antona, J.L. Gerard, A. Khayat, M. Massetti. - In: THE HEART SURGERY FORUM. - ISSN 1098-3511. - 8:6(2005 Dec), pp. E437-E442. [10.1532/HSF98.20051147]

Less Invasive Radial Artery Harvesting : Two Years' Experience

C. Antona;
2005

Abstract

Background. For coronary surgery we often use the radial artery (RA) instead of the saphenous vein, trying to exploit the advantages offered by this conduit. To eliminate the problems regarding alteration of upper-extremity function after RA procurement related to the standard conventional harvesting technique, we started using the less invasive harvesting technique with surprisingly good preliminary results. To compare the outcomes of open versus less invasive harvesting procedures, a prospective, nonrandomized study was developed by 2 centers. Methods. From January 2001 to March 2003, there were 87 consecutive patients in the less invasive radial artery harvesting (LIRAH) group and 90 patients in the conventional radial artery harvesting (CRAH) group. Patient characteristics and demographics were similar in the groups. Data collection was made to evaluate possible benefits of the LIRAH technique in terms of fewer forearm and hand complications, better aesthetics, and improved patient satisfaction. Results Between January 11, 2001, and March 30, 2003, 177 patients underwent either primary or redo coronary artery revascularizations with procurement of the RA for use as a conduit with the less invasive harvesting technique. The mean follow-up was 2 months. Four patients died, and overall mortality was 2.26%. One hundred seventy-three patients were successfully examined during the first postoperative control, 85 in the LIRAH group and 88 patients in the CRAH group. Objective and subjective data were collected from the consultant. The overall average age was 60.5 years (range, 40-77 years). In the LIRAH group, the mean overall incision length (when 2 incisions were necessary, both incision lengths were measured) was 5.6 cm (range, 4-10 cm), and the mean vessel length was 16 cm (range, 10-19 cm). Eighteen patients (20.6%) necessitated double incision. Mean harvesting time (from incision to skin closure) was 43.3 min (range, 25-70 min). Fourteen patients (16.4%) presented some kind of complication during the study. There were no cases with acute ischemia, bleeding, or re-exploration. Seventy-five patients (88.2%) found the cosmetic result excellent. Ten patients (11.8%) found it good, and none considered it mediocre. In the CRAH group, the mean incision length was 20 cm (range, 18-22 cm), and the mean vessel length was 18 cm (range, 17-20 cm ). Mean harvesting time (from incision to skin closure) was 30.8 min (range, 14-45 min). Thirty-four patients (38.6%) presented some kind of complication during the study. Three patients (3.5%) found the cosmetic result excellent. Forty-three (48.8%) found it good, and 42 (47.7%) considered it mediocre. Conclusions. A potential of fewer neurological forearm postoperative complications, better aesthetics, and improved patient satisfaction can be achieved by the LIRAH technique.
Settore MED/23 - Chirurgia Cardiaca
dic-2005
Article (author)
File in questo prodotto:
File Dimensione Formato  
Buklas and Gelpi.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 455.13 kB
Formato Adobe PDF
455.13 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/171857
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact