Glycated haemoglobin (HbA(1c)) is considered the 'gold standard' for monitoring metabolic control in diabetes. An International Expert Committee recently recommended HbA(1c) as a better method than measurement of glucose to use in the diagnosis of diabetes, based on its strong association with microvascular complications, a lower day-to-day variability and ease of use, not necessarily in the fasting state. These recommendations have been embraced by the American Diabetes Association (ADA), which stated in its Standards of Medical Care in Diabetes 2010 that "A(1c), fasting plasma glucose or the 2 h 75 g oral glucose tolerance test (OGTT) are appropriate for testing diabetes and assessing the risk of future diabetes," and that " a confirmed A(1c) >= 6.5% is diagnostic for diabetes." Measuring HbA(1c) has several advantages over glucose measurements, but its exclusive use should only be considered if the test is conducted under standardised conditions and its limitations are taken into due account. The impact of its use on the epidemiology of diabetes and other categories of glucose intolerance, as seen from recent reports, is also discussed.

The general use of glycated haemoglobin for the diagnosis of diabetes and other categories of glucose intolerance: still a long way to go / A. Lapolla, A. Mosca, D. Fedele. - In: NMCD. NUTRITION METABOLISM AND CARDIOVASCULAR DISEASES. - ISSN 0939-4753. - 21:7(2011), pp. 467-475.

The general use of glycated haemoglobin for the diagnosis of diabetes and other categories of glucose intolerance: still a long way to go

A. Mosca
Secondo
;
2011

Abstract

Glycated haemoglobin (HbA(1c)) is considered the 'gold standard' for monitoring metabolic control in diabetes. An International Expert Committee recently recommended HbA(1c) as a better method than measurement of glucose to use in the diagnosis of diabetes, based on its strong association with microvascular complications, a lower day-to-day variability and ease of use, not necessarily in the fasting state. These recommendations have been embraced by the American Diabetes Association (ADA), which stated in its Standards of Medical Care in Diabetes 2010 that "A(1c), fasting plasma glucose or the 2 h 75 g oral glucose tolerance test (OGTT) are appropriate for testing diabetes and assessing the risk of future diabetes," and that " a confirmed A(1c) >= 6.5% is diagnostic for diabetes." Measuring HbA(1c) has several advantages over glucose measurements, but its exclusive use should only be considered if the test is conducted under standardised conditions and its limitations are taken into due account. The impact of its use on the epidemiology of diabetes and other categories of glucose intolerance, as seen from recent reports, is also discussed.
Diabetes; Diagnosis; HbA(1c); Standardisation
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
2011_HbA1c_viewpoint_NMCD.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 168.12 kB
Formato Adobe PDF
168.12 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/164606
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 32
social impact