Established methods for evaluating cardiac function in small animals involve surgical manoeuvres. We describe a method for evaluating left ventricular volume (LVV) and pressure (LVP) in anaesthetised adult rats. Under fluoroscopic control a 23 G needle was inserted into the left ventricular cavity of anaesthetised normotensive WKY rats. LVV was determined by biplane angiography and LVP was measured directly. Surface electrocardiograms were recorded throughout the procedure. In 8 animals the study was repeated three times, one week apart. Animals were then sacrificed and tissues harvested for histological examination. In 8 rats, the technique was found to be reproducible and there was no evidence of functional (ECG) or pathological myocardial damage following repeated measurements. In conclusion this technique provides a reproducible method of measuring LVV and LVP, allowing longitudinal haemodynamic studies in anaesthetised rats.

A percutaneous approach to cardiac haemodynamics in anaesthetised rats / M. Ciulla, R. Meazza, N. Roberts, G. Branzi, F. Magrini. - In: CARDIOVASCULAR RESEARCH. - ISSN 0008-6363. - 23:1(1989 Jan), pp. 21-24. [10.1093/cvr/23.1.21]

A percutaneous approach to cardiac haemodynamics in anaesthetised rats

M. Ciulla
Primo
;
F. Magrini
Ultimo
1989

Abstract

Established methods for evaluating cardiac function in small animals involve surgical manoeuvres. We describe a method for evaluating left ventricular volume (LVV) and pressure (LVP) in anaesthetised adult rats. Under fluoroscopic control a 23 G needle was inserted into the left ventricular cavity of anaesthetised normotensive WKY rats. LVV was determined by biplane angiography and LVP was measured directly. Surface electrocardiograms were recorded throughout the procedure. In 8 animals the study was repeated three times, one week apart. Animals were then sacrificed and tissues harvested for histological examination. In 8 rats, the technique was found to be reproducible and there was no evidence of functional (ECG) or pathological myocardial damage following repeated measurements. In conclusion this technique provides a reproducible method of measuring LVV and LVP, allowing longitudinal haemodynamic studies in anaesthetised rats.
Rats; Heart; Animals; Rats, Inbred WKY; Blood Pressure; Anesthesia, Intravenous; Methods; Electrocardiography; Hemodynamics; Ventricular Function; Male; Stroke Volume
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore BIO/09 - Fisiologia
gen-1989
http://cardiovascres.oxfordjournals.org/content/23/1/21.long
Article (author)
File in questo prodotto:
File Dimensione Formato  
Cardiovasc Res 1989;23(1); 21-24.pdf

accesso solo dalla rete interna

Tipologia: Publisher's version/PDF
Dimensione 620.11 kB
Formato Adobe PDF
620.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/164403
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact