PURPOSE: The purpose of the present case report was to document a maxillary sinus floor augmentation procedure involving ligation of a blood vessel with a nearly 3-mm diameter in the lateral wall of the maxillary sinus. MATERIALS AND METHODS: A bilateral maxillary sinus floor augmentation procedure was performed in a 51-year-old healthy man. The preoperative computed tomography scan revealed a bony canal within the lateral maxillary sinus wall of the right as well as the left side close to the alveolar ridge. RESULTS: A vessel with a diameter of nearly 3 mm was identified during the sinus floor augmentation on the left side. The vessel was exposed and ligated. A vessel with a diameter of approximately 1 mm was identified on the right side and the sinus floor augmentation was performed without ligation. No complications were observed and the postoperative healing was uneventful. CONCLUSIONS: Although accidental laceration of vessels with an unusually large diameter during maxillary sinus floor augmentation is not life-threatening, impaired visualisation may compromise the augmentation procedure, including the elevation of the Schneiderian membrane. Moreover, postoperative bleeding and formation of a haematoma may occur. Therefore, ligation of vessels with an unusually large diameter is recommended during maxillary sinus floor augmentation to minimise intra- and postoperative complications.
Ligation of an unusually large vessel during maxillary sinus floor augmentation. A case report / T. Testori, G. Rosano, S.L.M. Taschieri, M. Del Fabbro. - In: EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY. - ISSN 1756-2406. - 3:3(2010), pp. 255-258.
Ligation of an unusually large vessel during maxillary sinus floor augmentation. A case report
G. RosanoSecondo
;S.L.M. TaschieriPenultimo
;M. Del FabbroUltimo
2010
Abstract
PURPOSE: The purpose of the present case report was to document a maxillary sinus floor augmentation procedure involving ligation of a blood vessel with a nearly 3-mm diameter in the lateral wall of the maxillary sinus. MATERIALS AND METHODS: A bilateral maxillary sinus floor augmentation procedure was performed in a 51-year-old healthy man. The preoperative computed tomography scan revealed a bony canal within the lateral maxillary sinus wall of the right as well as the left side close to the alveolar ridge. RESULTS: A vessel with a diameter of nearly 3 mm was identified during the sinus floor augmentation on the left side. The vessel was exposed and ligated. A vessel with a diameter of approximately 1 mm was identified on the right side and the sinus floor augmentation was performed without ligation. No complications were observed and the postoperative healing was uneventful. CONCLUSIONS: Although accidental laceration of vessels with an unusually large diameter during maxillary sinus floor augmentation is not life-threatening, impaired visualisation may compromise the augmentation procedure, including the elevation of the Schneiderian membrane. Moreover, postoperative bleeding and formation of a haematoma may occur. Therefore, ligation of vessels with an unusually large diameter is recommended during maxillary sinus floor augmentation to minimise intra- and postoperative complications.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.