Many regulatory agencies require that all building materials and industrial waste be tested for their naturally occurring radioactive material (NORM) concentrations before they can be used or thrown away. Usually the NORM concentrations of 40K, 232Th and 238U are measured by gamma-ray spectrometry using high-purity germanium or NaI(Tl) detectors. 40K is measured through its 1460.8 keV gamma line, which is mixed with 1459.2 keV line of 228Ac from the chain of 232Th. This fact ignored till now, requires a correction in the computation of 40K concentration. Although in many cases the error is <1%, there are cases where there have been higher errors. It should be emphasised that even if the correction in 40K concentration is large, the correction of the external dose index is negligible owing to the weighing factor being higher for 232Th than for 40K (by at least a factor of 10).

On the high-resolution gamma-ray spectrometric measurement of 40K in natural and synthetic materials / F.Groppi, N. Lavi, Z.B. Alfassi, M. Bonardi, C. Birattari. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - 115:1-4(2005), pp. 441-444.

On the high-resolution gamma-ray spectrometric measurement of 40K in natural and synthetic materials

F.Groppi
Primo
;
M. Bonardi
Penultimo
;
C. Birattari
Ultimo
2005

Abstract

Many regulatory agencies require that all building materials and industrial waste be tested for their naturally occurring radioactive material (NORM) concentrations before they can be used or thrown away. Usually the NORM concentrations of 40K, 232Th and 238U are measured by gamma-ray spectrometry using high-purity germanium or NaI(Tl) detectors. 40K is measured through its 1460.8 keV gamma line, which is mixed with 1459.2 keV line of 228Ac from the chain of 232Th. This fact ignored till now, requires a correction in the computation of 40K concentration. Although in many cases the error is <1%, there are cases where there have been higher errors. It should be emphasised that even if the correction in 40K concentration is large, the correction of the external dose index is negligible owing to the weighing factor being higher for 232Th than for 40K (by at least a factor of 10).
Radioprotezione; NORM; misure spettrometria gamma, potassio-40; materiali naturali ed artificiali; campioni
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Settore CHIM/03 - Chimica Generale e Inorganica
2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/15757
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact