Microbial activity acts as primer in the self combustion process of solid recovered fuels (SRF) during their storage or transport. Thus, EU gave mandate to the European Committee for Standardization (CEN) to develop biological methods, (i.e. respirometric method) able to assess the risk of potential self combustion of SRF. Real Dynamic Respiration Index (RDRI) was chosen as official method, and a validation procedure was requested, to assure the quality of the results, when the method is applied for official purpose, i.e. repeatability and reproducibility detection. Two SRF coming from full-scale plants were analyzed for RDRI by three laboratories in six replicates. Results indicated a good precision of the method proposed in agreement with other biological methods, i.e. relative standard deviations of repeatability ranged from 16.7% to 17.8%, and a relative standard deviations of reproducibility ranged from 17.5% to 23.9%.

Intra- and inter-laboratory variability in Real Dynamic Respiration Index (RDRI) method used to evaluate the potential rate of microbial self heating of solid recovered fuel / B. Scaglia, L. Paradisi, F. Adani. - In: BIORESOURCE TECHNOLOGY. - ISSN 0960-8524. - 102:3(2011), pp. 3591-3594. [10.1016/j.biortech.2010.10.066]

Intra- and inter-laboratory variability in Real Dynamic Respiration Index (RDRI) method used to evaluate the potential rate of microbial self heating of solid recovered fuel

B. Scaglia
Primo
;
F. Adani
Ultimo
2011

Abstract

Microbial activity acts as primer in the self combustion process of solid recovered fuels (SRF) during their storage or transport. Thus, EU gave mandate to the European Committee for Standardization (CEN) to develop biological methods, (i.e. respirometric method) able to assess the risk of potential self combustion of SRF. Real Dynamic Respiration Index (RDRI) was chosen as official method, and a validation procedure was requested, to assure the quality of the results, when the method is applied for official purpose, i.e. repeatability and reproducibility detection. Two SRF coming from full-scale plants were analyzed for RDRI by three laboratories in six replicates. Results indicated a good precision of the method proposed in agreement with other biological methods, i.e. relative standard deviations of repeatability ranged from 16.7% to 17.8%, and a relative standard deviations of reproducibility ranged from 17.5% to 23.9%.
Settore AGR/13 - Chimica Agraria
2011
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/149672
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact