ortho-Cresol (o-C) and meta-cresol (m-C) are minor urinary metabolites of toluene, a widely used chemical with neurotoxicological properties. A new assay for their determination in human urine is here proposed. Urinary cresol sulphates and glucuronates are submitted to acid hydrolysis, urine is neutralized, added with o-cresols-d8, and analytes are sampled in the headspace of urine by SPME using a polydimethylsiloxane fiber. Analysis is performed by GC/MS using, for separation, either a SupelcoWax10 (for o-C) or a chiral CP Cresol (for o-C and m-C) column. The method is very specific, with a range of linearity 0-5.0 mg/l, within- and between-run precision, as coefficient of variation, <15% and <19%, limit of detection of 0.006 mg/l for o-C and 0.007 mg/l for m-C. The procedure is applied to the quantification of cresols in urine from workers exposed to toluene and from subjects belonging to the general population.

Determination of urinary ortho- and meta-cresol in humans by headspace SPME gas chromatography-mass spectrometry / S. Fustinoni, R. Mercadante, L. Campo, L. Scibetta, C. Valla, V. Foa. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 817:2(2005 Mar), pp. 309-317. [10.1016/j.jchromb.2004.12.029]

Determination of urinary ortho- and meta-cresol in humans by headspace SPME gas chromatography-mass spectrometry

S. Fustinoni
Primo
;
L. Campo;L. Scibetta;V. Foa
Ultimo
2005

Abstract

ortho-Cresol (o-C) and meta-cresol (m-C) are minor urinary metabolites of toluene, a widely used chemical with neurotoxicological properties. A new assay for their determination in human urine is here proposed. Urinary cresol sulphates and glucuronates are submitted to acid hydrolysis, urine is neutralized, added with o-cresols-d8, and analytes are sampled in the headspace of urine by SPME using a polydimethylsiloxane fiber. Analysis is performed by GC/MS using, for separation, either a SupelcoWax10 (for o-C) or a chiral CP Cresol (for o-C and m-C) column. The method is very specific, with a range of linearity 0-5.0 mg/l, within- and between-run precision, as coefficient of variation, <15% and <19%, limit of detection of 0.006 mg/l for o-C and 0.007 mg/l for m-C. The procedure is applied to the quantification of cresols in urine from workers exposed to toluene and from subjects belonging to the general population.
Biological monitoring; Occupational exposure to toluene; Urinary cresols
Settore MED/44 - Medicina del Lavoro
mar-2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/14529
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 18
social impact